Tel.: (201) 792-0600 (800) 746-7303
Fax: (201) 792-4803
Email: simsite@simsite.com
NEWSLETTERS
February 2010 - Guide Bearings were NOT the problem More often then we would like to believe, guide bearings are incorrectly blamed for a problem January 2010 - Simsite® Impeller Save 20% on Energy Consumption! CASE STUDY: US Navy T-AKE Class Central Saltwater December 2009 - Re-designed Simsite® Impeller Simsite® Impeller Surpasses Bronze Impeller Performance November 2009 - Structural Composite Pumps Solve Corrosion Problems for Wastewater Purification Systems Advanced Water Purification (AWP) Systems for Royal Caribbean Cruise Lines. October 2009 - SIMSITE® Composite Ball Valve for US Navy 2-way ball valve designed for an operational pressure of 300psi. September 2009 - German Navy: 6 x 4 - 13 Fire Pump for Oil Recovervy Oil recovery system pump certified by Germanischer Lloyd for safe use at sea. August 2009 - Halliburton: Chemical Process 8 x 6 - 13 ANSI Pump Deep water acidizing system (33% HCl) for breaking rock formations July 2009 - U.S. Navy: SIMSITE® Structural Composite Non-Magnetic Fire Pump for Minesweeper First vertical Structural Composite Pump to pass shock and vibration tests for U.S. Navy June 2009 - Halliburton: SIMSITE® Structural Composite Pump for Acid Blending System 3 x 2 - 8 and 4 x 3 - 8 Hydraulically Driven SIMSITE® Chemical Pumps for transferring HCl and NH4Cl
February 2010 - Guide Bearings were NOT the problem
More often then we would like to believe, guide bearings are incorrectly blamed for a problem
January 2010 - Simsite® Impeller Save 20% on Energy Consumption!
CASE STUDY: US Navy T-AKE Class Central Saltwater
December 2009 - Re-designed Simsite® Impeller
Simsite® Impeller Surpasses Bronze Impeller Performance
November 2009 - Structural Composite Pumps Solve Corrosion Problems for Wastewater Purification Systems
Advanced Water Purification (AWP) Systems for Royal Caribbean Cruise Lines.
October 2009 - SIMSITE® Composite Ball Valve for US Navy
2-way ball valve designed for an operational pressure of 300psi.
September 2009 - German Navy: 6 x 4 - 13 Fire Pump for Oil Recovervy
Oil recovery system pump certified by Germanischer Lloyd for safe use at sea.
August 2009 - Halliburton: Chemical Process 8 x 6 - 13 ANSI Pump
Deep water acidizing system (33% HCl) for breaking rock formations
July 2009 - U.S. Navy: SIMSITE® Structural Composite Non-Magnetic Fire Pump for Minesweeper
First vertical Structural Composite Pump to pass shock and vibration tests for U.S. Navy
June 2009 - Halliburton: SIMSITE® Structural Composite Pump for Acid Blending System
3 x 2 - 8 and 4 x 3 - 8 Hydraulically Driven SIMSITE® Chemical Pumps for transferring HCl and NH4Cl
Sims Pump Valve Co., Inc. 1314 Park Ave. Hoboken, N.J. 07030 U.S.A.